Freephone 080097 09486
Standard Rate 01782 745848
Items: 0 Total: £ 0.00

Replacement element lookup guide. Whether you are replacing a worn-out bulb in a commercial workshop heater, marqueeheater, or outdoor patio heater, fitting the correct wattage, length, and cap fitting (R7s or SK15) is essential forsafe operation. Use the list below to match your heater manufacturer and model to its compatible replacement bulb. Clickon any product link to view full specifications, exact dimensions, and ordering details.


500 Watt Infrared Heater Bulb – Heatmaster U3 (RUB194)

Heatmaster U3, Heatmaster U4
Heatmaster U3B Favourite, Heatmaster U3 Popular
Motif Popular parasol heater
500 Watt Infrared Heater Bulb – Heatmaster U3 (RUB194) >>


450 – 500 Watt Gold Bulb – Heatmaster U3 (PHI195)

Heatmaster U3, Heatmaster U4
Heatmaster U3B Favourite, Heatmaster U3 Popular
Motif Popular parasol heater
450 – 500 Watt Gold Bulb – Heatmaster U3 (PHI195) >>

750 Watt R7 200 mm Ruby Heater Lamp Bulb (RUB451)

Tansun Carnival, Cosy Camper, Cosy Paws
750 Watt R7 200 mm Ruby Heater Lamp Bulb (RUB451) >>

1 kW 1000 Watt Ruby Halogen Infrared Heater Lamp Bulb (RUB943)

White Gala Marquee Heater
No further verified models; does not suit 1.2/1.3 kW wall-mounted heaters.
1 kW 1000 Watt Ruby Halogen Infrared Heater Lamp Bulb (RUB943) >>

1.2 kW 1200 Watt Ruby Halogen Infrared Heater Lamp Bulb (RUB333)

Pyramid, Tansun Algarve, Helios, Sundance, Levante LEVQ12 / LEVQ12W
Burda Gold, Star Progetti, Varma heat-outdoors
Sunswitch 1.3 kW glass-fronted patio heater, Victory HLO 13, Tansun Algarve One, Tansun Algarve Two
1.2 kW 1200 Watt Ruby Halogen Infrared Heater Lamp Bulb (RUB333) >>

1.3 kW 1300 Watt Ruby Heater Lamp Bulb Element (RUB192)

Suitable for standard 1.2–1.3 kW wall-mounted and free-standing heaters.
Tansun Algarve, Burda Gold, Star Progetti, Helios, Varma heat-outdoors
Sunswitch 1.3 kW glass-fronted, Sundance, Victory HLO 13, Tansun Algarve One, Tansun Algarve Two
1.3 kW 1300 Watt Ruby Heater Lamp Bulb Element (RUB192) >>

Gold 1300 Watt 1.3 kW Outdoor Heater Bulb (PHI197)

Tansun Algarve
Burda Gold, Star Progetti, Helios, Varma heat-outdoors
Sunswitch 1.3 kW glass-fronted, Sundance, Victory HLO 13, Tansun Algarve One, Tansun Algarve Two
Gold 1300 Watt 1.3 kW Outdoor Heater Bulb (PHI197) >>

800 Watt Ruby Slimline Heater Bulb (RUB611)

Heatmaster Slimline Super 2400 W
La Hacienda / Heatmaster U2BS-R24
Not suitable for Heatmaster Popular or Favourite models.
800 Watt Ruby Slimline Heater Bulb (RUB611) >>

Gold 800 Watt Infrared Heater Bulb (PHI611)

Heatmaster Slimline Super 2400 W
La Hacienda / Heatmaster U2BS-R24
Gold 800 Watt Infrared Heater Bulb (PHI611) >>

1.1 kW 348mm Infrared Heater Bulb R7 – Rhino TQ3 TQ4 (RUB976)

Rhino TQ3 (HO29400), Rhino TQ4 2.2 kW, Clarke equivalents
Rhino CH3
1.1 kW 348mm Infrared Heater Bulb R7 – Rhino TQ3 TQ4 (RUB976) >>

110 Volt 1.1 kW 348mm Infrared Heater Bulb R7 (RUB976-110)

Rhino TQ3 / TQ4 110 V
Rhino CH3 110 V
110 Volt 1.1 kW 348mm Infrared Heater Bulb R7 (RUB976-110) >>

1.4 kW 348mm Ruby Heater Bulb R7 (RUB603)

Rhino TQ3 (240 V), Broughton RG308, Elite Heat, Clarke Devil 370SPC
Clarke Devil 370PD (1400/2800 W)
Sealey IR15
Clarke 370PC, VOSE HE42
Birchwood TQ 3000, TQ-5334
1.4 kW 348mm Ruby Heater Bulb R7 (RUB603) >>

110 Volt 1.4 kW 348mm Ruby Heater Bulb R7 (RUB454)

Rhino TQ3 110 V
Rhino CH3 110 V
110 Volt 1.4 kW 348mm Ruby Heater Bulb R7 (RUB454) >>

1.5 kW 348mm Ruby Heater Bulb R7 (RUB469)

Clarke Devil 370, 370PB, 370SPB, 370SP, 370SPC, 370P, 355SP
Sealey IRC153, Prem-I-Air EH0208
Big Red Rad / Prem-I-Air Big Rad 3 kW
No further verified models found.
1.5 kW 348mm Ruby Heater Bulb R7 (RUB469) >>

110 Volt 1.5 kW 348mm Ruby Heater Bulb R7 (RUB770)

Clarke Devil 371P, 371SP, 371PB, 371SPB, 355SP, 355P
Sealey IRC153 / IRS153 (110 V versions)
110 Volt 1.5 kW 348mm Ruby Heater Bulb R7 (RUB770) >>

1500 Watt 1.5 kW Ruby SK15 Heater Lamp Bulb (SKA551)

Tansun Rio, Tansun Sorrento, Hyco SK1500
Tansun Sorrento Single 1.5 kW, Double 3 kW, Triple 4.5 kW (each model comes with either a 1.5 or 2 kW lamp)
Robinson Willey Optik 1-15, Optik 2-30, Varma comfort heaters, Solaira SCOSYAW15240
1500 Watt 1.5 kW Ruby SK15 Heater Lamp Bulb (SKA551) >>

Gold 1500 Watt 1.5 kW SK15 Bulb (SKA745)

Tansun Rio, Tansun Sorrento, Hyco SK1500
Tansun Sorrento Single 1.5 kW, Double 3 kW, Triple 4.5 kW
Robinson Willey Optik 1-15, Optik 2-30, Varma comfort heaters, Solaira SCOSYAW15240
Gold 1500 Watt 1.5 kW SK15 Bulb (SKA745) >>

2000 Watt 2 kW Ruby SK15 Heater Lamp Bulb (SKA701)

Tansun Sorrento 2, 3 and 4; Tansun Algarve 2 kW; Dimplex OPH20
Tansun Sorrento Single 2 kW, Double 4 kW, Triple 6 kW
Tansun Sorrento SOR220IP
2000 Watt 2 kW Ruby SK15 Heater Lamp Bulb (SKA701) >>

2 kW Gold SK15 Bulb – Fits Tansun Sorrento 2kW (SKA746)

Tansun Sorrento 2 kW, Tansun Algarve 2 kW, Dimplex OPH20
Tansun Sorrento Double 4 kW, Triple 6 kW
Tansun Sorrento SOR220IP
2 kW Gold SK15 Bulb – Fits Tansun Sorrento 2kW (SKA746) >>

Patio Heater Tube Bulb Element Pack – Electrovision Prem-I-Air EH1324 (EH1324-3)

Electrovision Prem-I-Air EH0368 and EH1224
HQH2000W, PHP-2000DI, Status HOPH-2000W ST04
Firefly OL1822, HEATSURE, LIVIVO 2 kW
Patio Heater Tube Bulb Element Pack – Electrovision Prem-I-Air EH1324 (EH1324-3) >>

TQ3 Output Explained

There has been some confusion surrounding the heat output of the Rhino TQ3 infrared heater, with differentspecifications quoting either 2.8kW (2800W) or 2.2kW (2200W) for what appears to be the same model. Both ratings haveappeared in product literature, and the discrepancy can be explained by differences in the heating elements fittedduring the TQ3's production history.

Early Rhino TQ3 specifications dating back to 2008 list a maximum heat output of 2.8kW, achieved using two 1400W quartzinfrared heating elements. Rhino's 2017 catalogue also specifies twin 1400W elements, confirming that the 2.8kWconfiguration was used for a considerable period. However, other TQ3 specifications quote a reduced output of 2.2kW,achieved using two 1100W elements. This shows that the heater's specification was revised during its production life,although the exact date of the change has not been established.

Importantly, the different outputs appear under the same TQ3 model designation, meaning that the model name alone is notsufficient to identify which replacement heating elements are required. The original 2.8kW TQ3 requires two 1400Welements, while the 2.2 kW TQ3 requires two 1100W elements. Both versions use quartz infrared elements, and replacementlamps share the same physical dimensions and R7s fitting.

When replacing a failed element, it is essential to establish the heater's original rated output before ordering replacements. Fitting 1400W elements to a heater designed for 1100W elements would increase its electrical load beyondthe intended specification, potentially overloading internal wiring, switches or other components. Conversely, fitting1100W elements to an original 2.8kW heater would reduce its maximum heat output to 2.2kW, although suitability shouldstill be confirmed against the manufacturer's requirements. Replacement elements must also match the heater's operatingvoltage, as 110V and 230/240V versions are not interchangeable.

The Rhino TQ3 has since been superseded by the Rhino TQ4, which is specified at 2.2kW using two 1100W heating elements.The TQ4 also introduces electronic temperature controls and additional operating features. This newer 2.2kWspecification may contribute to confusion when comparing replacement elements for the older TQ3.

In summary, the Rhino TQ3 has been documented with two different heat outputs: 2.8kW using twin 1400W elements and 2.2kWusing twin 1100W elements. Owners should not rely solely on the TQ3 model name when purchasing replacement bulbs.Instead, they should check the heater's rating plate, original documentation or existing element specifications toidentify the correct wattage and voltage.


Understanding 230V and 110V Heaters and Replacement Bulbs

Many of the infrared heaters including Rhino and Clarke are manufactured in two different voltage versions: a 230Vversion (220–240V) designed for standard UK mains electricity, and a 110V version (100–120V) primarily intended forconstruction sites and industrial environments. Although both versions look similar and operate in the same way, theyuse heating elements specifically designed for their respective supply voltages. It is therefore essential to selectreplacement bulbs with the correct voltage rating as well as the correct wattage.


Why are the voltages shown as 220–240V and 100–120V?

Electrical equipment is commonly described using a nominal voltage, such as 230V or 110V. However, electricitysupplies do not always operate at precisely these figures, and electrical equipment is often designed to accommodate arange of supply voltages.

In the UK, the standard domestic electricity supply is nominally 230V, although the actual voltage can vary. Thepermitted UK mains supply tolerance is generally 230V +10% / −6%, equivalent to approximately 216–253V. Historically,the UK used a nominal 240V supply, while much of continental Europe used 220V. The adoption of a common Europeannominal voltage of 230V explains why many electrical products are labelled 220–240V.

Similarly, 110V equipment may be marked 100–120V, indicating the voltage range for which the equipment or component isdesigned. This covers several lower-voltage electrical systems, including nominal 100V, 110V and 120V supplies.However, not every individual bulb is necessarily suitable for the entire range, so its manufacturer's voltage ratingmust always be checked.

On UK construction sites, 110V equipment is commonly supplied through a yellow site transformer, usually providing acentre-tapped-to-earth supply. This arrangement gives approximately 55V between either live conductor and earth,reducing the severity of certain electric-shock risks compared with ordinary 230V equipment.


Why do 110V and 230V heaters require different bulbs?

Although the 110V and 230V Rhino TQ3 heaters may use quartz infrared bulbs of identical physical dimensions andsimilar appearance, the electrical characteristics of the bulbs are different.

A heating element works by passing an electrical current through a resistive filament, generating heat and infraredradiation. The resistance of the filament is designed around a particular operating voltage and power output.

For example, a 1400W heating element designed for 230V has a nominal operating resistance of approximately 37.8 ohms,whereas a 1400W element designed for 110V has a nominal operating resistance of approximately 8.6 ohms. These areapproximate hot operating values; actual resistance varies with temperature.

This means that two bulbs can produce exactly the same 1400W heat output while requiring very different voltages andelectrical currents.

Bulb specification230V version110V version
1100W bulb current4.8A10.0A
1400W bulb current6.1A12.7A
2 × 1100W total output2200W2200W
2 × 1400W total output2800W2800W
Current at 2800W12.2A25.5A

Figures are approximate and calculated at nominal supply voltage.

This illustrates why 110V heaters require considerably more current than equivalent 230V heaters to produce the sameheat output. Consequently, the 110V version must have appropriately rated wiring, switches, connectors and powersupply equipment.


What happens if the wrong voltage bulb is fitted?

Fitting a 110V bulb into a 230V heater is extremely dangerous. The bulb would receive approximately twice its intendedvoltage, potentially producing around four times its rated power before failing. This could cause the element to burnout almost immediately, with a risk of overheating, electrical damage or fire.

Conversely, fitting a 230V bulb into a 110V heater would result in substantially reduced heat output. A 1400W bulbdesigned for 230V would produce only around 320W when supplied with 110V, based on its nominal operating resistance.The actual output may differ because filament resistance changes with temperature.

A 110V bulb must never be substituted for a 230V bulb, or vice versa, even if both have the same wattage, length andfittings.


Selecting the correct replacement bulbs for the Rhino TQ3

When purchasing replacement quartz infrared bulbs for a Rhino TQ3, two separate specifications must be considered: theheater's operating voltage and its original heat output.

The TQ3 has been documented with both 2.8kW and 2.2kW outputs. The 2.8kW version uses two 1400W heating elements,while the 2.2kW version uses two 1100W elements.

Heater versionRequired replacement bulbs
TQ3 – 230V, 2.8kW2 × 1400W, 230V
TQ3 – 230V, 2.2kW2 × 1100W, 230V
TQ3 – 110V, 2.8kW2 × 1400W, 110V
TQ3 – 110V, 2.2kW2 × 1100W, 110V

These are the electrical specifications corresponding to each heater configuration; the original rating plate andmanufacturer-approved replacement part should be checked before purchase.


Summary

The 220–240V and 100–120V descriptions refer to the electrical supply voltages for which the heaters or replacementelements are designed. They do not indicate different heating capacities or levels of heat output. A 110V heaterfitted with two 1400W elements can produce the same 2800W of heat as an equivalent 230V heater fitted with two 1400Welements, provided each is operating at its intended rated voltage.

The important distinction is that voltage determines which electrical version of the bulb is required, while wattagedetermines its heat output.

For the Rhino TQ3, this means checking both specifications independently. A 2.8kW heater requires 1400W elements,while a 2.2kW heater requires 1100W elements, and in both cases the bulbs must be rated for the correct supplyvoltage.

The safest approach is always to check the heater's rating plate and original specification rather than relying solelyon the TQ3 model designation or the physical appearance of the replacement bulb.

110 Volt (100 - 120V) Infrared Heater Bulbs >>

Message Us